Designed for LED lighting and signage applications
Universal AC input (100~305VAC)
Built-in active PFC provide PF>0.9 over entire input range
Class 2 power supply
Convection cooled, plastic, UL94V0 case
? -40°C ~ +70°C ambient, Tcase <= 90°C
Protection: Short circuit/Over voltage
? Automatic over-temperature current foldback
Class A Noise Rating
Dimmable output with flexible architecture (Optional)
? DC Dimming (0-10V)
5 year warranty
產品參數:
Orderable Part Numbers
Part Number*1, *2 |
Maximum Output Current (mA) |
Output Voltage |
Maximum Efficiency |
Maximum Output |
XEL-A025B-024-C1X40-ZA01 |
1400 |
8 ~ 18 |
83% |
25 |
XEL-A025B-024-C1X25-ZA01 |
1250 |
12 ~ 20 |
83% |
25 |
XEL-A025B-024-C1X05-ZA01 |
1050 |
15 ~ 24 |
85% |
25 |
XEL-A025B-042-CX800-ZA01 |
800 |
20 ~ 30 |
85% |
25 |
XEL-A025B-042-CX700-ZA01 |
700 |
25 ~ 36 |
86% |
25 |
XEL-A025B-042-CX600-ZA01 |
600 |
30 ~ 42 |
86% |
25 |
XEL-A025B-056-CX500-ZA01 |
500 |
36 ~ 48*3 |
87% |
25 |
XEL-A025B-056-CX450-ZA01 |
450 |
40 ~ 56*3 |
87% |
25 |
XEL-A025B-056-CX350-ZA01 |
350 |
40 ~ 56*3 |
88% |
20 |
General Specification
SERIES |
XEL-A025B |
|
OUTPUT |
DC VOLTAGE RANGE |
8 ~ 56Vdc (see orderable parts table for details) |
RATED CURRENT RANGE |
0.35A to 1.40A (see orderable parts table for details) |
|
RATED POWER |
25W (see orderable parts table for details) |
|
LOAD REGULATION1 |
±5% |
|
TURN ON TIME |
< 1S, (10% - 100% dimming) |
|
INPUT |
VOLTAGE RANGE |
100 ~ 305Vac |
FREQUENCY RANGE |
47 – 63Hz |
|
POWER FACTOR (Typ.) |
PFC >0.90, >= 70% Rated Power, 120-277VAC Input |
|
THD (TOTAL HARMONIC DIST.) |
- Compliance to EN61000-3-2 Class C Standards |
|
EFFICIENCY (Typ.) |
≥ 82% , >= 80% Rated Power, 120-277VAC Input |
|
AC INPUT CURRENT (Max.) |
0.35A @ 120VAC, 0. 20A @ 277VAC |
|
INRUSH CURRENT (Typ.) |
15A @ 120VAC, 20A @ 277VAC, <10msec duration, Cold start at 25oC |
|
LEAKAGE CURRENT |
<500μA (400μA typical) |
|
DIMMING |
MODES |
0-10 VDC, Sinking and Sourcing (See dimming curve) |
PROTECTION |
SHORT CIRCUIT |
Hiccup mode protection. Recovers automatically after fault condition is removed |
OVER VOLTAGE |
The driver would cut off output current if Vf is greater than No-load output voltage. Recovers automatically after fault condition is removed. |
|
OVER TEMPERATURE |
Automatic fold-back, Tc >90°C (-0/+5C). Output reduced in steps from 100% to 15%. |
ENVIRONMENT |
WORKING TEMPERATURE |
Tambient: -40°C ~ +70°C |
WORKING HUMIDITY |
5% ~ 95% RH non-condensing |
|
STORAGE TEMPERATURE |
-40°C ~ + 85°C ambient |
|
STORAGE HUMIDITY |
5% ~ 95% RH non-condensing |
|
Waterproof Rating |
IP66 Compliant |
|
IMPACT RESISTANCE |
1 g/s |
|
VIBRATION |
5-55Hz/2g, 30 minutes |
|
SAFETY & EMC |
SAFETY STANDARDS |
UL8750, CAN/CSA-C22.2 No. 250.13-12, UL1310, CSA22.2 No. 223 (<42V output) |
EMI CONDUCTION & RADIATION |
FCC Part 15 Class B and EN55015 Compliant |
|
HARMONIC CURRENT |
Compliance to GB4343-2003+A1, CISPR 14-1:EN61000-3-2:1995 |
|
EMS IMMUNITY |
Compliance to GB/T13926.3, IEC61000-4-3 & 4-4, PrEN55014-2 Section 6.2 & 6.5, IEC61000-4-11. |
|
TRANSIENT SUPPRESSION |
IEC61000-4-5 LEVEL 4 (2KV/1KA L-L) |
|
RELIABILITY |
DESIGN LIFETIME |
50,000 hours @ Tcase ≤ 90°C |
25W LED驅動電源 | PDF文件下載 |
---|---|
HR25L-25W | 點擊下載 |
XEL-A025B | 點擊下載 |